Abstract: The depth of concrete cracks is an important parameter for evaluating the safety and durability of components, and the ultrasonic single-sided flat measurement method is the most widely used non-destructive testing method on site.
If the testing personnel only follow the standard and do not understand the principle, it often leads to misjudgment when faced with actual engineering conditions such as narrow crack width, water accumulation or filling in cracks, inclined cracks, and dense steel bars in the testing area.
This article is aimed at engineering testing technicians to systematically explain the basic principles of ultrasonic single-sided flat measurement method based on relevant standards, with a focus on analyzing the mechanism of the influence of crack width on detection accuracy.
This article takes a 100 kHz planar transducer as an example to quantitatively discuss the issue of “when the crack width is so small that the ultrasonic flat measurement method is no longer applicable”, which is a common concern among testing personnel.
.
Professor Qian Xiaoqian from Zhejiang University proposed the “eight hour curing concept” based on the characteristics of modern concrete and the summary of engineering practice and theoretical research; Professor Gan Changcheng proposed the concept of “perfect wet curing” for early concrete based on extensive engineering practice; Professor Sun Zhenping from Tongji University conducted in-depth research and analysis on the complexity of modern concrete working environment and the causes of early crack formation, and summarized the “three in one prevention system for early cracking of concrete”.
These research results have great guiding significance for us to better understand concrete cracks and prevent them.
.
The combination coefficient of live load on the floor of special function rooms is taken as the default value of the software, and the calculation result tends to be unsafe.
.
After the concrete pouring or completion of the components, the construction unit should develop a corresponding construction and maintenance plan based on the structure, environmental conditions, and other factors.
.
With the rapid development of commercial concrete, there is an increasing phenomenon of both supply and demand sides arguing over the low strength of structural concrete.
As the commercial concrete industry belongs to the buyer’s market, in order to timely recover payment and continue to cooperate with the demand side, most enterprises have to make concessions and passively bear some economic responsibilities.
.
According to Article 3.
6.
6 and Article 6.
1.
15 of the “Seismic Design Standard for Buildings” GB/T50011-2010; Technical Specification for Concrete Structures of Tall Buildings JGJ 3-2010, Clause 6.
1.
4-4; 22G101-2 “Drawing Rules and Construction Details for Overall Representation of Concrete Structure Construction Drawings (Cast in place Concrete Plate Stairs)”, pages 1-3, relevant structural requirements.
.
The quality problems of the steel bars themselves lead to rust stains on the surface of the steel bars, which further develop into a rust layer on the entire surface of the steel bars, resulting in expansion of the steel bars, reduced adhesion between the steel bars and the concrete, and separation from the concrete.
The concrete itself undergoes damage, resulting in cracks along the reinforcement and detachment of the concrete.
At this point, the corrosion and expansion of steel bars will exacerbate the development of concrete cracks.
As shown in the following figure:.
The factors affecting the width of cracks in reinforced concrete components are numerous and complex, and it is still a topic of discussion, mainly including the following aspects.
.