When conducting a house safety appraisal, for structures that have suffered damage due to fire, earthquake, or other reasons, or for components that have serious defects found during construction and use, as well as for structures with performance degradation and functional changes, such as floor cracking and steel corrosion, if investigation, testing, and verification analysis are not sufficient to evaluate the structural performance, load tests can be conducted to verify their actual structural performance indicators, providing a basis for further processing.
For example, when evaluating the bearing capacity of cast-in-place floor slabs with a small number of non stress cracks, it is generally possible to analyze and judge the thickness, reinforcement, concrete strength, and crack distribution characteristics of the floor slab based on detection data and experience.
When there are a large number of non stress cracks in the floor slab, due to the existing conventional structural analysis techniques, it is not yet possible to quantitatively consider the impact of cracks on the bearing capacity and stiffness of the floor slab.
Load tests can be considered to accurately evaluate the structural performance of the floor slab.
.