How long can GFRP reinforcement in concrete withstand high temperatures? This study provides the answer

The concrete protective layer can significantly delay the tensile performance degradation of GFRP reinforcement at high temperatures, but it will lose its protective effect above 400 ℃; This article proposes a residual strength prediction model based on heat absorption parameters, providing a theoretical basis for the fire protection design of GFRP reinforced concrete structures.

Magnetic Thread Disc

.

The Influence and Research Progress of SAP on the Performance of High Performance Concrete

High performance concrete is widely used in key infrastructure projects due to its advantages such as low water cement ratio, high strength, and high density.

However, low water cement ratio systems are prone to significant self drying effects during the hydration process, leading to self shrinkage and early microcracks, reducing structural durability and limiting their engineering applications.

Swift Lift Void Former

Super absorbent resin (SAP) is a three-dimensional network cross-linked polymer additive with strong water absorption, retention, and slow-release capabilities.

It can form a “micro reservoir” inside concrete and continuously replenish water and inhibit shrinkage through internal curing.

It is a new functional material that improves the crack resistance and durability of high-performance concrete.

This article summarizes the material properties, modification mechanism, impact on concrete performance, and future research directions of SAP based on domestic and foreign research results.

.

Trial molds have standardized requirements, and there are also operational requirements for the formation of test blocks. Concrete standard

The laboratory is not only the main department for controlling the quality of concrete, but also the core of technological development and development.

At the same time, it is also the window for the external image of the enterprise and the top priority for concrete enterprises.

Rebar Bolsters

Therefore, high-quality inspection tools can enable experimenters to obtain real data, have a clear understanding, save energy and reduce consumption for enterprises, and safeguard quality.

The standard test block obtained through standard trial molding is the only prerequisite for obtaining real and standard data.

.

Excessive concrete loss, adjusting with water reducing agent, case analysis

A certain project said, “The slump of freshly mixed concrete was lost in 10 minutes, causing dozens of cubic meters of concrete to be unable to be constructed.

Your admixture manufacturer should come and adjust it quickly, and you will be responsible for the economic losses caused!” After the accident, we immediately set off and arrived at the site to replace the raw materials of the concrete one by one using the elimination method, observe the working performance of the concrete, and ultimately lock the cause on the washed sand.

Rebar Saddles

.

The fifth measure to reduce concrete bleeding: construction

Try to avoid adding admixtures and water twice, which can cause significant differences in the bleeding rate of concrete in the same truck; Avoid water accumulation on the inner wall of the template, which can cause obvious water marks and color differences; Avoid excessive vibration, which can cause the slurry to float, bleed, and secrete.