What are the maintenance requirements for outdoor concrete facades, bridges, walls, and other components after painting

In the construction of outdoor concrete facades, bridges, and wall components, many practitioners have a misconception that the completion of protective coating means the completion of all protective construction.

However, in many engineering projects, wall whitening and partial peeling occur in the later stage, and the protective effect does not meet expectations.

Edge Lift Anchor

The reason for this is mostly not due to the quality of the painting construction, but rather the neglect of the maintenance process.

.

Analysis and determination of cracks in concrete engineering

The cracks generated in concrete structures under load are called stress cracks.

Concrete Lifting Clutch

Ordinary concrete components may experience stress cracks when subjected to 30% to 40% of the design load, and the ultimate failure load of such components is often more than 1.

5 times the design load value.

As long as the width of such cracks meets the specifications, it will not affect the safety of the structure.

.

How to make permanent identification for precast components? The complete process path from steel mold reverse printing to sleeve marking

After the deployment of precast buildings, the “identity management” of precast concrete components (PC components) has become an unavoidable process.

A laminated board and a precast wall panel must be connected by identification from factory to lifting, from acceptance and accountability to later operation and maintenance.

Pfeifer VS Box

.

Research on the Repair of Surface Bulging Problems in Concrete Structures

The use of polymer modified cement mortar for repair treatment not only provides good restraint on the surface of concrete structures, but also effectively isolates moisture and air from entering the interior of concrete components, and effectively suppresses potential expansion stresses in the future.

It has a reinforcing effect on concrete components, ensuring durability meets the original design requirements.

This article takes a project in Yuelu District, Changsha as an example to address the widespread problem of bursting and bulging on the surface of concrete structures.

Lifting Anchor

Based on on-site inspection and analysis results, targeted technical measures are proposed to provide some reference for the repair and treatment of large-scale surface bulging problems in high-rise or super high-rise concrete structures.

.

Chengdu UHPC building facade component manufacturer: eaves waistline, balcony railing, precast canopy, why do detailed components also use

Sichuan Kunshengyu New Building Materials Co.

, Ltd.

(Kunshengyu) is located in Shaqu Street, Dayi County, Chengdu City.

It focuses on the research and manufacturing of UHPC ultra-high performance concrete and GRC glass fiber reinforced concrete products.

UHPC building facade detailed components are a specialized product line of Kunshengyu for building facades – eaves lines, waistlines, window frames, balcony railings, precast canopy eaves, decorative lines, etc.

They are replicated with UHPC molds, precast in factories, and installed on site to serve residential, office, hotel, commercial and other projects, providing one-stop services from detailed design to finished product delivery.

Ferrule Loop Insert

.

The impact and harm of non-standard construction on concrete quality at the construction site

Whether the strength of concrete occurs and develops regularly, whether surface defects of concrete can be controlled, and whether the durability of concrete can meet the service life are closely related to the construction technology, construction details, and curing of concrete on the construction site.

This article briefly discusses the impact and harm of non-standard construction on concrete quality at the construction site.

Elephant Foot Ferrule

.